Reliability Assessment of Linear Ultrasonic Transducers Under Dynamic Environmental Conditions

Автори

  • Angelina Dimitrova TU Varna

##semicolon##

https://doi.org/10.29114/ajtuv.vol9.iss2.364

##semicolon##

Linear transducer, piezoelectric degradation, thermal cycling, reliability

Абстракт

Linear ultrasonic transducers are essential for medical diagnostic imaging, yet their behavior under dynamic environmental conditions remains insufficiently characterized. This study examines typical failure modes of linear array transducers exposed to extreme temperatures and humidity relevant to field applications. Using accelerated ageing tests and electrical parameter monitoring, we outline dominant degradation mechanisms in piezoelectric materials such as PZT ceramics. Results show that thermal cycling leads to noticeable decreases in piezoelectric and dielectric performance, accompanied by increased dielectric losses. SEM and XRD analyses reveal progressive microstructural deterioration, including grain damage, rising porosity, and partial amorphization. A threshold temperature above which degradation accelerates markedly is identified, and predictive models for estimating remaining useful life are proposed.

Изтегляния

Данни за теглене още не са налични.

##submission.citations##

Szabo, T. L. (2014), Diagnostic Ultrasound Imaging: Inside Out, 2nd ed. Boston, MA: Academ-ic Press, 2014, doi: https://doi.org/10.1016/C2011-0-07261-7.

Hoskins, P.R. (2011), Principles of ultrasound elastography, Ultrasound. 2011;20(1):8-15. doi:10.1258/ult.2011.011005.

Grazhdani, H., David, E., Ventura Spagnolo, O., Buemi, F., Perri, A., Orsogna, N., Gigli, S., Chimenz, R. (2018), Quality assurance of ultrasound systems: current status and review of literature, J Ultrasound. 2018 Sep;21(3):173-182. doi: 10.1007/s40477-018-0304-7.

Dimitrova, А. (2025), Reliability testing of control systems in medical ultrasound equipment, in Proc. 16th Nat. Conf. Electronics 2025, Sofia, Bulgaria.

Chen, W.P. & Chan, H. & Yiu, F. & Ng, K. & Liu, P. (2002), Water-Induced Degradation in Lead Zirconate Titanate Piezoelectric Dermics. Applied Physics Letters, Vol. 80/19, pp. 3587-3589. DOI: 10.1063/1.1479205.

Wang, L., Li, B., Hu, B. et al. (2022), Failure mode effect and criticality analysis of ultrasound device by classification tracking, BMC Health Serv Res 22, 429, https://doi.org/10.1186/s12913-022-07843-4.

Smith, W. A. (1989), The role of piezocomposites in ultrasonic transducers, Proceedings., IEEE Ultrasonics Symposium, Montreal, QC, Canada, 1989, pp. 755-766 vol.2, DOI: 10.1109/ULTSYM.1989.67088.

Nakamura, K. (2012), Ultrasonic Transducers: Materials and Design for Sensors, Actuators and Medical Applications, Cambridge, UK: Woodhead Publishing, 2012.

Dimitrova, A. (2025), Thermal stability and failure of piezoelectric materials under temperature shocks, in Proc. 16th Nat. Conf. Electronics 2025, Sofia, Bulgaria, 2025.

Vaskeliene, V., Sliteris, R., Kazys, R.J., Zukauskas, E., Mazeika, L. (2023), Development and Investigation of High-Temperature Ultrasonic Measurement Transducers Resistant to Multiple Heating–Cooling Cycles, Sensors 2023, 23, 1866

##submission.downloads##

Публикуван

2025-12-30

##submission.howToCite##

Dimitrova, A. (2025). Reliability Assessment of Linear Ultrasonic Transducers Under Dynamic Environmental Conditions. ГОДИШНИК НА ТЕХНИЧЕСКИ УНИВЕРСИТЕТ - ВАРНА, 9(2), 89–94. https://doi.org/10.29114/ajtuv.vol9.iss2.364

Брой

Раздел (Секция)

ЕЛЕКТРОТЕХНИКА, ЕЛЕКТРОНИКА И АВТОМАТИКА

Подобни статии

<< < 1 2 

Можете също да прегледате стартирайте разширено търсене за подобни статии във връзка с тази статия.